Protection garment to protect human life from electrical flashes Made fromspecial flame-resistant fabric (FR) meeting IEC 61482-1 & IEC 61482-2 Standards and tested as per ASTM1959 Classified as per HRC 1, HRC 2, HRC 3, HRC 4 based on ATPV values as per NFPA70 E Standard Used while working in electrical switchgear control boardrooms, motor control board operations  and steel…
Medium Voltage Heat Shrink/ Fusion tapes. HVBT heat-shrinkable tape is ideal for use on complex shapes and where busbars cannot be disconnected. HVBT tape shrinks 30% longitudinally and an adhesive layer flows and seals the layers of tape during installation. As with the other components in the system, the adhesive does not bond to metalwork, allowing easy removal for inspection…
Raychem Electrical Insulating Composite Gloves are high-performance safety gloves that combine: Electrical insulation Mechanical protection Arc-flash resistance within one integrated glove system. They provide superior worker safety, comfort, flexibility, and durability while reducing the need for separate over-gloves. Their compliance with IEC and EN standards, bi-colour safety design, and resistance to harsh industrial conditions make them ideal for professional electrical…
Raychem Electrical Insulating Gloves Designed to protect workers from electric shock when working on energized electrical equipment. Made from insulating rubber and tested to international safety standards (IEC 60903 / EN 60903). Available in different voltage classes: Class 00: up to 500 V AC Class 0: up to 1,000 V AC Class 1: up to 7.5 kV AC Class 2:…
Raychem Electrical Insulating Gloves are essential safety gear for electricians and technicians, offering reliable protection against electrical hazards. Made from natural rubber with high dielectric strength, they combine safety, comfort, flexibility, and durability. Available in multiple voltage classes and rigorously tested to international standards, these gloves ensure safe handling of electrical systems across low to high voltage applications. These gloves…
Raychem Electrical Insulating Gloves are essential safety gear for electricians and technicians, offering reliable protection against electrical hazards. Made from natural rubber with high dielectric strength, they combine safety, comfort, flexibility, and durability. Available in multiple voltage classes and rigorously tested to international standards, these gloves ensure safe handling of electrical systems across low to high voltage applications.
Raychem Electrical Insulating Mats are safety rubber mats designed to protect workers from electric shock while operating near live electrical equipment such as panels, switchboards, transformers, and substations. These mats are made from high-quality dielectric rubber with anti-skid surfaces and comply with IEC 61111 safety standards. They are flame retardant, resistant to oil and chemicals, and available in different voltage…
Raychem Electrical Insulating Mats are safety rubber mats designed to protect workers from electric shock while operating near live electrical equipment such as panels, switchboards, transformers, and substations. These mats are made from high-quality dielectric rubber with anti-skid surfaces and comply with IEC 61111 safety standards. They are flame retardant, resistant to oil and chemicals, and available in different voltage…
Raychem Electrical Insulating Mats are safety rubber mats designed to protect workers from electric shock while operating near live electrical equipment such as panels, switchboards, transformers, and substations. These mats are made from high-quality dielectric rubber with anti-skid surfaces and comply with IEC 61111 safety standards. They are flame retardant, resistant to oil and chemicals, and available in different voltage…
Raychem Electrical Insulating Mat (DEA0020994) : Electrical insulating safety mat for use near energized electrical equipment. Dimensions: 0.6 m (width) × 1 m (length) Thickness: 4.3 mm Color: Dark Grey Surface: Corrugated, glossy finish for improved grip and anti-slip performance. Suitable for AC and DC electrical applications. Commonly used in front of switchboards, control panels, substations, transformer rooms, and power…
Raychem Electrical Insulating Mat (DEA0020994) Electrical insulating safety mat for use near energized electrical equipment. Dimensions: 0.6 m (width) × 1 m (length) Thickness: 4.3 mm Color: Dark Grey Surface: Corrugated, glossy finish for improved grip and anti-slip performance. Suitable for AC and DC electrical applications. Commonly used in front of switchboards, control panels, substations, transformer rooms, and power distribution…
High quality Insulating mats conforming to Standards IEC 61111 & AS/NZS IEC6111:2020 High quality rubber provides complete protection against electric shock due to earth faults Suitable for applications and placed in front of electrical panels, switchgears and high voltage equipment for safe working environment for operators/users Choice of Class must be determined according to the maximal nominal voltage of network…
High quality Insulating blanket conforming to Standard IEC 61112 Protection of personnel from accidental contact with live or earthed electrical conductors, apparatus or circuits and avoidance of short circuits on electrical installations Made of elastomer of high dielectric properties Electrical insulating blankets conform to IEC 61112
Providing electrical and mechanical protection, the gloves are available in bicolour from 500 VAC to 17500 V AC KAMFET Electrical Insulating Gloves protect people working on live voltages or in proximity of electrical installations from electrical shocks Used for a wide range of voltages from 500 V AC upto 17000 V AC Compliant with EN60903:2003, IEC60903:2014 and CE category III…
How They’re Used These mats are typically placed on the floor in front of electrical panels, switchboards, battery rooms, and other live installations so that anyone standing on them with the right PPE (insulated gloves/boots) has a layer of insulation between their body and ground, reducing shock risk.
Insulating rubber gloves are personal protective equipment (PPE) designed to protect workers from electrical shock when working with or near live electrical circuits. Made from high-quality, non-conductive rubber, these gloves are essential for electricians, linemen, and maintenance personnel operating in high-voltage environments.
Leather over gloves/ protector worn over rubber gloves for protection against mechanical hazards Used with rubber insulating gloves to enhance mechanical protection Velcro at the cuffs adjust the tightness to the user's hand
Raychem MV Surge Arresters (up to 52 kV) Raychem MV surge arresters (up to 52 kV) are metal-oxide (ZnO), gapless protective devices used to safeguard medium-voltage power systems from lightning and switching overvoltages. They use MOV (metal oxide varistor) technology with no spark gaps, giving fast response and better protection levels. The arresters have polymeric (silicone rubber) housing, which is…
🔹 Summary of Raychem MV Surge Arresters (up to 52 kV) Raychem MV surge arresters (up to 52 kV) are metal-oxide (ZnO), gapless protective devices used to safeguard medium-voltage power systems from lightning and switching overvoltages. They use MOV (metal oxide varistor) technology with no spark gaps, giving fast response and better protection levels. The arresters have polymeric (silicone rubber)…
Raychem MV surge arresters (up to 52 kV) are metal-oxide (ZnO), gapless protective devices used to safeguard medium-voltage power systems from lightning and switching overvoltages. They use MOV (metal oxide varistor) technology with no spark gaps, giving fast response and better protection levels. The arresters have polymeric (silicone rubber) housing, which is moisture-resistant, pollution-resistant, and non-shattering. Designed as per IEC…
Raychem MV surge arresters (up to 52 kV) are metal-oxide (ZnO), gapless protective devices used to safeguard medium-voltage power systems from lightning and switching overvoltage. They use MOV (metal oxide varistor) technology with no spark gaps, giving fast response and better protection levels. The arresters have polymeric (silicone rubber) housing, which is moisture-resistant, pollution-resistant, and non-shattering. Designed as per IEC…
Raychem RPG Electrical Insulating Gloves are safety gloves designed to protect workers from electric shock and arc-flash hazards while working on energized electrical equipment. They are made from high-quality insulating rubber and comply with international safety standards such as IEC 60903 and EN 60903.
Superior Environmental Sealing:Raychem sleeves often feature an internal adhesive lining (such as hot-melt adhesive) that melts when heated, providing a waterproof, airtight, and corrosion-resistant seal for cable joints, splices, and repairs. High-Performance Material:They are typically made from radiation-crosslinked polyolefin, which offers exceptional resistance to abrasion, chemicals, and mechanical stress, making them durable in harsh environments. Versatile Shrink Ratios:They possess high…
Installation Tips Heat Application: A hot air gun is used to shrink the tape, typically requiring temperatures over 200°C for specialized tapes like RT-555, the adhesive flows to bond layers together sealing the assembly.
 Quick Tips When working on energized equipment, always use gloves with a class rating above the system’s voltage. For arc flash hazards, use composite/arc-rated gloves designed to withstand specific arc energy levels. Use leather over-gloves for mechanical protection (abrasion, puncture). Store and handle insulating gloves carefully to avoid damage. Periodic dielectric testing is required to maintain safety certification. Electrical gloves…